Reference data
Thermal properties of common materials
Compare representative material properties used in heat-transfer calculations. Keep the condition note beside every value because temperature, composition, density, moisture, direction and manufacturing method can change real properties.
Compare materials
Select up to four materials. The comparison keeps property conditions visible so the numbers stay connected to their physical context.
| Compare | Material and source | Category | Thermal conductivity k W/(m·K) | Specific heat cp J/(kg·K) | Density ρ kg/m³ | Calculated diffusivity α mm²/s |
|---|---|---|---|---|---|---|
| Silver Representative values near room temperature for high-purity silver. Purity and temperature affect conductivity. Source: NIST/NBS thermophysical-property literature; representative room-temperature values · checked 2026-08-13 | Metal | 429 | 235 | 10490 | 174.026 | |
| Copper Reference-metal values near 295 K. NIST lists density 8.96 g/ml, linear expansion 16.66×10^-6/K and thermal conductivity 400 W/(m·K) at 295 K; cp is representative near room temperature. Source: NIST Reference Tables and thermophysical-property references · checked 2026-08-13 | Metal | 400 | 385 | 8960 | 115.955 | |
| Aluminium Representative values near 295 K. Alloy and temper can materially change conductivity and expansion. Source: NIST Reference Tables and aluminium property references · checked 2026-08-13 | Metal | 235 | 897 | 2700 | 97.031 | |
| Gold Representative values near 295 K; specific heat is a room-temperature comparison value. Source: NIST Reference Tables · checked 2026-08-13 | Metal | 317 | 129 | 19300 | 127.325 | |
| Iron Representative room-temperature values for iron. Purity, phase and temperature affect properties. Source: NIST thermophysical-property literature; representative room-temperature values · checked 2026-08-13 | Metal | 80.4 | 449 | 7870 | 22.753 | |
| Nickel Representative room-temperature values for nickel. Source: NIST thermophysical-property literature; representative room-temperature values · checked 2026-08-13 | Metal | 90.9 | 444 | 8900 | 23.003 | |
| Lead NIST lists density, expansion and conductivity near 295 K; cp is representative near room temperature. Source: NIST Reference Tables · checked 2026-08-13 | Metal | 35 | 128 | 11310 | 24.177 | |
| Stainless steel 304 Representative values near room temperature. Stainless grades and temperature vary. Source: NIST Reference Tables and engineering property references · checked 2026-08-13 | Metal | 15 | 500 | 8000 | 3.750 | |
| Brass, 70Cu-30Zn Representative room-temperature values; brass properties vary with composition and processing. Source: NIST copper-alloy property references · checked 2026-08-13 | Metal | 120 | 380 | 8500 | 37.152 | |
| Titanium alloy Ti-6Al-4V Representative near-room-temperature values. Heat treatment and exact grade condition matter. Source: NIST cryogenic materials property reference literature; room-temperature representative values · checked 2026-08-13 | Metal | 6.7 | 526 | 4430 | 2.875 | |
| Alumina ceramic Representative dense alumina near room temperature. Conductivity changes substantially with purity, porosity and temperature. Source: Representative engineering range; verify supplier grade for design · checked 2026-08-13 | Ceramic | 25 | 880 | 3900 | 7.284 | |
| Soda-lime glass Representative room-temperature values. Composition and processing affect properties. Source: Representative materials reference values; use product data for design · checked 2026-08-13 | Ceramic | 1 | 840 | 2500 | 0.476 | |
| Borosilicate glass Representative room-temperature values; formulation and temperature affect properties. Source: Representative engineering values; verify manufacturer data for design · checked 2026-08-13 | Ceramic | 1.1 | 830 | 2230 | 0.594 | |
| HDPE Representative room-temperature values for high-density polyethylene. Grade, crystallinity and temperature affect properties. Source: Representative polymer engineering range; verify resin grade for design · checked 2026-08-13 | Polymer | 0.45 | 1900 | 950 | 0.249 | |
| Nylon 6 Representative dry room-temperature values. Moisture uptake and formulation can change thermal properties. Source: NIST polymer property literature and representative engineering values · checked 2026-08-13 | Polymer | 0.25 | 1700 | 1130 | 0.130 | |
| PTFE Representative room-temperature values. Grade, fillers and temperature affect properties. Source: Representative polymer engineering values; verify product data for design · checked 2026-08-13 | Polymer | 0.25 | 1000 | 2200 | 0.114 | |
| Normal-weight concrete Illustrative normal-weight concrete. Conductivity varies strongly with density, aggregate, moisture and temperature. Source: Building-science reference range; use project-specific data for design · checked 2026-08-13 | Building material | 1.4 | 880 | 2300 | 0.692 | |
| Common brick Representative masonry values. Density, porosity, moisture and firing process cause substantial variation. Source: Representative building-material range; use tested assembly data for design · checked 2026-08-13 | Building material | 0.72 | 840 | 1920 | 0.446 | |
| Gypsum board Representative room-condition values. Board density and moisture affect properties. Source: Representative building-material range; use product data for rated assemblies · checked 2026-08-13 | Building material | 0.17 | 1090 | 800 | 0.195 | |
| Softwood, across grain Illustrative dry softwood. Wood is anisotropic, species-dependent and moisture-sensitive. Source: Representative building-material range · checked 2026-08-13 | Building material | 0.12 | 1600 | 500 | 0.150 | |
| Fiberglass insulation Illustrative low-density fibrous insulation. Use manufacturer-rated resistance or conductivity for a real product and temperature range. Source: DOE Building Science Education insulation context · checked 2026-08-13 | Insulation | 0.04 | 840 | 20 | 2.381 | |
| Mineral wool insulation Representative insulation value. Density, binder, temperature and product construction affect performance. Source: Representative insulation range; use manufacturer-rated product data · checked 2026-08-13 | Insulation | 0.04 | 840 | 80 | 0.595 | |
| Expanded polystyrene insulation Representative EPS insulation values. Density, blowing process and temperature affect conductivity. Source: Representative insulation range; use manufacturer-rated product data · checked 2026-08-13 | Insulation | 0.036 | 1300 | 20 | 1.385 | |
| Water, liquid Approximate liquid water near 25 °C and atmospheric pressure. Values change with temperature and pressure. Source: NIST thermophysical properties of fluids · checked 2026-08-13 | Liquid | 0.606 | 4181 | 997 | 0.145 | |
| Ethylene glycol Approximate pure liquid near room temperature. Water-glycol mixtures have composition-dependent properties. Source: Representative fluid values; use composition- and temperature-specific data for engineering · checked 2026-08-13 | Liquid | 0.252 | 2380 | 1110 | 0.095 | |
| Air, dry Approximate dry air near 25 °C and 1 atm. Properties change with temperature, pressure and composition. Source: NIST AIRPROPS / thermophysical-properties references · checked 2026-08-13 | Gas | 0.026 | 1006 | 1.184 | 21.828 | |
| Carbon dioxide, gas Approximate gas values near 25 °C and 1 atm. CO2 properties vary with state, especially near phase boundaries and the critical region. Source: NIST thermophysical properties of fluids · checked 2026-08-13 | Gas | 0.0166 | 846 | 1.8 | 10.901 |
What the four properties tell you
Thermal conductivity, k, describes how readily a temperature gradient drives conductive heat flow through a material. Its SI unit is W/(m·K). For the same area, thickness and temperature difference, a high-conductivity layer carries more conductive heat than a low-conductivity layer.
Specific heat capacity, cp, describes the sensible energy required to raise the temperature of one kilogram of material by one kelvin under stated conditions. It is an energy-storage property. It does not tell you how quickly a temperature disturbance moves through an object.
Density, ρ, connects mass and volume. The product ρcp is volumetric heat capacity, which estimates how much sensible energy a unit volume stores for each kelvin of temperature change.
Thermal diffusivity, α, combines transport and storage through α = k/(ρcp). A high value means a temperature disturbance tends to spread through a material relatively quickly. The table calculates diffusivity from the displayed k, cp and density values so the derived result stays consistent with those inputs.
Why copper, water and insulation behave so differently
Copper has very high thermal conductivity compared with common insulation, so it can spread heat effectively through a heat sink, pan base or heat exchanger. Fibrous insulation serves the opposite purpose. Its low effective conductivity helps resist heat flow across a layer.
Water shows why conductivity alone is incomplete. Liquid water does not conduct heat like copper, but its high specific heat lets each kilogram absorb substantial energy for a modest temperature rise. That makes water useful in thermal storage and many heat-transfer systems. In an actual tank or pipe, fluid motion can make convection more important than conduction.
No single thermal property ranks materials from best to worst. A material can be useful because it spreads heat, resists heat flow, stores energy, responds quickly to a changing boundary condition or combines several of those behaviours.
A worked comparison using thermal diffusivity
Thermal diffusivity is calculated as conductivity divided by volumetric heat capacity. Copper combines high conductivity with substantial density, while water combines modest conductivity with high specific heat. Their calculated diffusivities are therefore very different.
This helps explain why temperature changes can spread through a metal object much faster than through a comparable distance of still water when conduction dominates. In liquids, natural or forced convection can move energy much faster than molecular conduction alone, so diffusivity should be interpreted within the actual transport process.
Geometry can matter as much as material choice
Thermal conductivity belongs to a material under stated conditions. Thermal resistance belongs to a particular heat-flow path. For a simple plane layer, resistance increases with thickness and decreases with conductivity and area. A thick layer of a moderately conductive material can therefore resist heat flow more effectively than a very thin layer of a lower-conductivity material.
The same distinction matters in electronics and cookware. A thin copper layer can spread heat laterally while another layer supplies strength. A thermal interface material can conduct far less effectively than the adjoining metal but still improve the complete path by replacing microscopic air gaps and reducing contact resistance.
Temperature, moisture and composition can change the numbers
Thermal properties are condition-dependent. Metal alloy and temper can affect conductivity. Wood varies by species, moisture content and grain direction. Concrete varies with aggregate, density and moisture. Insulation depends on product structure, density, temperature and moisture. Fluid properties vary with temperature, pressure and composition.
That is why every row retains a condition note and source context. Representative values can support education, comparison and preliminary estimates. Product selection, equipment design and safety-critical calculations should use data for the actual material grade or product over the relevant operating range.
Material values are different from assembly ratings
A conductivity value is not an R-value or U-value. R-value describes resistance for a layer or assembly and depends on geometry. U-value describes overall thermal transmittance through an assembly and may include several layers, surface films, framing and other heat-flow paths.
Specific heat also does not determine the thermal mass of an element by itself. The amount of material and its density matter. Comparing complete assemblies therefore requires geometry, boundary conditions and construction details in addition to material-property data.
How to choose a value for a calculation
First match the material as closely as practical: composition, grade, density and physical form matter. Then check whether the reference temperature, moisture level or pressure resembles the intended application. Finally, match the quality of the data to the decision. A representative value may be enough for a sensitivity calculation, while design work may require manufacturer data, a standard, a temperature-dependent correlation or a laboratory measurement.
Do not copy a value without its conditions. Apparent disagreement between reputable references often reflects different temperatures, compositions, test methods or material states rather than a simple error in one table.
How to read the source notes
Some rows use values tabulated directly by an authoritative reference for a stated condition. Others are clearly marked as representative engineering values because a broad material name such as concrete, softwood or fibrous insulation does not identify one unique formulation or product. The condition note tells you which situation applies.
The displayed check date records when the cited context was reviewed for this reference. It does not make a condition-dependent property a universal constant. For precise work, follow the source and confirm that its material definition and test conditions match the problem you are solving.
Use these properties in calculations
Use the Heat Transfer Explorer to see how conductivity affects conduction, the Specific Heat Calculator to connect mass and temperature change to energy, and the Thermal Diffusivity Calculator to combine conductivity, density and specific heat.
For building assemblies, use the Multi-Layer Wall Calculator and read the guides to thermal conductivity, thermal diffusivity and thermal resistance.